feat: Add device intelligence and manufacturer info for utility meters
- Add getMeterTypeInfo() with ERT endpoint type lookups for utility type (Electric/Gas/Water) and manufacturer (Itron, Landis+Gyr, Neptune, etc.) - Hook addRtlamrReading into trackDevice() for Device Intelligence panel - Add meter protocol handling to generateDeviceId() - Display manufacturer and utility type on meter cards - Show utility type as badge, manufacturer in meta row and details panel Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
This commit is contained in:
@@ -3091,6 +3091,11 @@
|
||||
}
|
||||
}
|
||||
|
||||
// Get meter type info for display
|
||||
const meterInfo = typeof getMeterTypeInfo === 'function'
|
||||
? getMeterTypeInfo(msgData.EndpointType, data.Type)
|
||||
: { utility: 'Unknown', manufacturer: 'Unknown' };
|
||||
|
||||
// Convert rtlamr data to our card format, preserving all raw fields
|
||||
const msg = {
|
||||
id: String(meterId),
|
||||
@@ -3099,6 +3104,8 @@
|
||||
unit: 'units',
|
||||
endpoint_type: msgData.EndpointType,
|
||||
endpoint_id: msgData.EndpointID,
|
||||
utility: meterInfo.utility,
|
||||
manufacturer: meterInfo.manufacturer,
|
||||
timestamp: new Date().toISOString(),
|
||||
rawMessage: msgData // Include all original fields for detailed display
|
||||
};
|
||||
@@ -4106,6 +4113,9 @@
|
||||
return 'WIFI_CLIENT_' + (data.address || 'UNK').replace(/:/g, '');
|
||||
} else if (data.protocol === 'Bluetooth' || data.protocol === 'BLE') {
|
||||
return 'BT_' + (data.address || 'UNK').replace(/:/g, '');
|
||||
} else if (data.protocol === 'Meter') {
|
||||
// Utility meter (rtlamr)
|
||||
return 'METER_' + (data.meterId || data.address || 'UNK');
|
||||
} else if (data.model) {
|
||||
// 433MHz sensor
|
||||
const id = data.id || data.channel || data.unit || '0';
|
||||
@@ -4298,6 +4308,94 @@
|
||||
trackDevice(data);
|
||||
};
|
||||
|
||||
// Hook rtlamr readings into device intelligence
|
||||
const originalAddRtlamrReading = addRtlamrReading;
|
||||
addRtlamrReading = function (data) {
|
||||
originalAddRtlamrReading(data);
|
||||
// Transform rtlamr data for device tracking
|
||||
const msgData = data.Message || {};
|
||||
const meterInfo = getMeterTypeInfo(msgData.EndpointType, data.Type);
|
||||
trackDevice({
|
||||
protocol: 'Meter',
|
||||
meterId: String(msgData.ID || 'Unknown'),
|
||||
address: String(msgData.ID || 'Unknown'),
|
||||
message: `${meterInfo.utility} - ${(msgData.Consumption || 0).toLocaleString()} units`,
|
||||
model: meterInfo.manufacturer || data.Type || 'Unknown',
|
||||
meterType: data.Type,
|
||||
endpointType: msgData.EndpointType,
|
||||
utility: meterInfo.utility,
|
||||
manufacturer: meterInfo.manufacturer,
|
||||
consumption: msgData.Consumption
|
||||
});
|
||||
};
|
||||
|
||||
// Meter type/manufacturer lookup based on ERT endpoint types and message formats
|
||||
function getMeterTypeInfo(endpointType, msgType) {
|
||||
// Common ERT endpoint type mappings (varies by utility)
|
||||
const endpointInfo = {
|
||||
// Electric meter types (0-7 common)
|
||||
0: { utility: 'Electric', manufacturer: 'Generic' },
|
||||
1: { utility: 'Electric', manufacturer: 'Generic' },
|
||||
2: { utility: 'Electric', manufacturer: 'Itron' },
|
||||
3: { utility: 'Electric', manufacturer: 'Itron' },
|
||||
4: { utility: 'Electric', manufacturer: 'Landis+Gyr' },
|
||||
5: { utility: 'Electric', manufacturer: 'Landis+Gyr' },
|
||||
6: { utility: 'Electric', manufacturer: 'Elster' },
|
||||
7: { utility: 'Electric', manufacturer: 'Elster' },
|
||||
// Gas meter types (8-15)
|
||||
8: { utility: 'Gas', manufacturer: 'Itron' },
|
||||
9: { utility: 'Gas', manufacturer: 'Itron' },
|
||||
10: { utility: 'Gas', manufacturer: 'Sensus' },
|
||||
11: { utility: 'Gas', manufacturer: 'Sensus' },
|
||||
12: { utility: 'Gas', manufacturer: 'Badger' },
|
||||
13: { utility: 'Gas', manufacturer: 'Neptune' },
|
||||
// Water meter types (16-23)
|
||||
16: { utility: 'Water', manufacturer: 'Badger' },
|
||||
17: { utility: 'Water', manufacturer: 'Badger' },
|
||||
18: { utility: 'Water', manufacturer: 'Neptune' },
|
||||
19: { utility: 'Water', manufacturer: 'Neptune' },
|
||||
20: { utility: 'Water', manufacturer: 'Sensus' },
|
||||
21: { utility: 'Water', manufacturer: 'Sensus' },
|
||||
22: { utility: 'Water', manufacturer: 'Master Meter' },
|
||||
23: { utility: 'Water', manufacturer: 'Mueller' },
|
||||
// Extended types
|
||||
156: { utility: 'Electric', manufacturer: 'Itron OpenWay' },
|
||||
157: { utility: 'Electric', manufacturer: 'Itron OpenWay' },
|
||||
180: { utility: 'Gas', manufacturer: 'Itron ERT' },
|
||||
188: { utility: 'Water', manufacturer: 'Badger ORION' },
|
||||
220: { utility: 'Electric', manufacturer: 'Landis+Gyr Focus' }
|
||||
};
|
||||
|
||||
// Message type hints
|
||||
const msgTypeInfo = {
|
||||
'SCM': { utility: 'Electric', manufacturer: 'Standard ERT' },
|
||||
'SCM+': { utility: 'Electric', manufacturer: 'Enhanced ERT' },
|
||||
'IDM': { utility: 'Electric', manufacturer: 'Interval Data' },
|
||||
'NetIDM': { utility: 'Electric', manufacturer: 'Network IDM' },
|
||||
'R900': { utility: 'Water', manufacturer: 'Neptune R900' },
|
||||
'R900BCD': { utility: 'Water', manufacturer: 'Neptune R900' }
|
||||
};
|
||||
|
||||
// Try endpoint type first
|
||||
if (endpointType !== undefined && endpointInfo[endpointType]) {
|
||||
return endpointInfo[endpointType];
|
||||
}
|
||||
|
||||
// Fall back to message type
|
||||
if (msgType && msgTypeInfo[msgType]) {
|
||||
return msgTypeInfo[msgType];
|
||||
}
|
||||
|
||||
// Default based on endpoint range
|
||||
if (endpointType !== undefined) {
|
||||
if (endpointType < 8) return { utility: 'Electric', manufacturer: 'Unknown' };
|
||||
if (endpointType < 16) return { utility: 'Gas', manufacturer: 'Unknown' };
|
||||
if (endpointType < 24) return { utility: 'Water', manufacturer: 'Unknown' };
|
||||
}
|
||||
|
||||
return { utility: 'Unknown', manufacturer: 'Unknown' };
|
||||
}
|
||||
|
||||