Remove wrong timestamp correction from diag

This commit is contained in:
Markus Unterwaditzer
2026-02-03 20:31:46 +01:00
committed by Will Greenberg
parent fd63210bf9
commit 2781b3c7ed
3 changed files with 10 additions and 6 deletions
+1 -1
View File
@@ -10,7 +10,7 @@ use std::sync::RwLock;
static CLOCK_OFFSET: RwLock<TimeDelta> = RwLock::new(TimeDelta::zero());
/// Get the current clock offset.
pub fn get_offset() -> TimeDelta {
fn get_offset() -> TimeDelta {
*CLOCK_OFFSET.read().unwrap()
}
+1 -2
View File
@@ -360,8 +360,7 @@ impl Timestamp {
let mut delta_seconds = ts_upper as f64 * 1.25;
delta_seconds += ts_lower as f64 / 40960.0;
let ts_delta = chrono::Duration::milliseconds(delta_seconds as i64);
// Apply global clock offset to adjust for incorrect device time
epoch + ts_delta + crate::clock::get_offset()
epoch + ts_delta
}
}