mirror of
https://github.com/Next-Flip/Momentum-Firmware.git
synced 2026-07-06 22:48:10 -07:00
fix: gate auto poweroff timer only for Timer mode
* Missed the legacy countdown timer arming when `Auto PowerOff` is set to `OFF` or `Percent`.
This commit is contained in:
@@ -489,6 +489,7 @@ static void power_auto_poweroff_timer_callback(void* context) {
|
||||
|
||||
//start|restart timer and events subscription and callbacks for input events (we restart timer when user press keys)
|
||||
static void power_auto_poweroff_arm(Power* power) {
|
||||
if(power->settings.auto_poweroff_mode != PowerAutoPoweroffModeTimer) return;
|
||||
if(power->settings.auto_poweroff_delay_ms) {
|
||||
if(power->input_events_subscription == NULL) {
|
||||
power->input_events_subscription = furi_pubsub_subscribe(
|
||||
@@ -535,7 +536,8 @@ static void power_loader_callback(const void* message, void* context) {
|
||||
// apply power settings
|
||||
static void power_settings_apply(Power* power) {
|
||||
//apply auto_poweroff settings
|
||||
if(power->settings.auto_poweroff_delay_ms && !power->app_running) {
|
||||
if(power->settings.auto_poweroff_mode == PowerAutoPoweroffModeTimer &&
|
||||
power->settings.auto_poweroff_delay_ms && !power->app_running) {
|
||||
power_auto_poweroff_arm(power);
|
||||
} else if(power_is_running_auto_poweroff_timer(power)) {
|
||||
power_auto_poweroff_disarm(power);
|
||||
|
||||
Reference in New Issue
Block a user