Smittix 2eea28da05 Fix Morse decoder silent on real HF signals via AGC and warm-up
Add automatic gain control (AGC) before Goertzel processing to normalize
quiet audio from direct sampling mode where the -g gain flag has no effect.
Fix broken adaptive threshold bootstrap by adding a 50-block warm-up phase
that collects magnitude statistics before seeding noise floor and signal peak.
Lower threshold ratio from 50% to 30% for better weak-CW sensitivity.