The slant correction was severely under-correcting because bwd=50 caused
the sync deviation measurements to saturate after only ~25 lines (for a
2-sample/line SDR clock drift). Lines 25-256 all reported deviation=-50,
pulling the linear regression slope toward zero.
Increase bwd and fwd to 800 samples each — sufficient to track cumulative
drift from up to ~±200 ppm SDR clock offset across the full 256-line image.
Also use a full-sync-length (432-sample) Goertzel window instead of 1/3
length, giving ~111 Hz frequency resolution to cleanly separate the 1200 Hz
sync tone from 1500 Hz pixel data. Search is stepped at 5 samples (~0.1 ms)
for efficiency, keeping the goertzel_batch batch size at ~320 windows/line.