# TP-Link M7350
|
|
|
|
Supported in Rayhunter since version 0.3.0.
|
|
|
|
The TP-Link M7350 supports many more frequency bands than Orbic and therefore works in Europe and also in some Asian and African countries.
|
|
|
|
## Supported Bands
|
|
|
|
| Technology | Bands |
|
|
| ---------- | ----- |
|
|
| 4G LTE | B1/B3/B7/B8/B20 (2100/1800/2600/900/800 MHz) |
|
|
| 3G | B1/B8 (2100/900 MHz) |
|
|
| 2G | 850/900/1800/1900 MHz |
|
|
|
|
*Source: [TP-Link Official Product Page](https://www.tp-link.com/baltic/service-provider/lte-3g/m7350/)*
|
|
|
|
## Hardware versions
|
|
|
|
The TP-Link comes in many different *hardware versions*. Support for installation varies:
|
|
|
|
* `1.0`, `2.0`: **Not supported**, devs are not able to obtain a device
|
|
* `3.0`, `3.2`, `5.0`, `5.2`, `7.0`, `8.0`: **Tested, no known issues since 0.3.0.**
|
|
* `6.2`: **One user reported it is working, not tested**
|
|
* `4.0`: **Manual firmware downgrade required** ([issue](https://github.com/EFForg/rayhunter/issues/332))
|
|
* `9.0`: **Working since 0.3.2.**
|
|
|
|
TP-Link versions newer than `3.0` have cyan packaging and a color display. Version `3.0` has a one-bit display and white packaging.
|
|
|
|
You can find the exact hardware version of each device under the battery or next to the barcode on the outer packaging, for example `V3.0` or `V5.2`.
|
|
|
|
When filing bug reports, particularly with the installer, please always specify the exact hardware version.
|
|
|
|
You can get your TP-Link M7350 from:
|
|
|
|
* First check for used offers on local sites, sometimes it's much cheaper there.
|
|
* [Geizhals price comparison](https://geizhals.eu/?fs=tp-link+m7350).
|
|
* [Ebay](https://www.ebay.com/sch/i.html?_nkw=tp-link+m7350&_sacat=0&_from=R40&_trksid=p4432023.m570.l1313).
|
|
|
|
## Installation & Usage
|
|
|
|
Follow the [release installation guide](./installing-from-release.md). Substitute `./installer orbic` for `./installer tplink` in other documentation. The Rayhunter UI will be available at <http://192.168.0.1:8080>.
|
|
|
|
## Obtaining a shell
|
|
|
|
Unlike on Orbic, the installer will not enable ADB. Instead, you can obtain a root shell with the following command:
|
|
|
|
```sh
|
|
./installer util tplink-start-telnet
|
|
telnet 192.168.0.1
|
|
```
|
|
|
|
## Display states
|
|
|
|
If your device has a color display, Rayhunter will show the same red/green/white line at the top of the display as it does on Orbic, each color meaning "warning"/"recording"/"paused" respectively. See [Using Rayhunter](./using-rayhunter.md).
|
|
|
|
If your device has a one-bit (black-and-white) display, Rayhunter will instead show an emoji to indicate status:
|
|
|
|
* `!` means "warning (potential IMSI catcher)"
|
|
* `:)` (smiling) means "recording"
|
|
* `:` (face with no mouth) means "paused"
|
|
|
|
## Power-saving mode/sleep
|
|
|
|
By default the device will go to sleep after N minutes of no devices being connected. In that mode it will also turn off connections to cell phone towers.
|
|
In order for Rayhunter to record continuously, you have to turn off this sleep mode in TP-Link's admin panel (go to **Advanced** - **Power Saving**) or keep e.g. your phone connected on the TP-Link's WiFi.
|
|
|
|
## Port triggers
|
|
|
|
On hardware revisions starting with v4.0, the installer will modify settings to
|
|
add two port triggers. You can look at `Settings > NAT Settings > Port
|
|
Triggers` in TP-Link's admin UI to see them.
|
|
|
|
1. One port trigger "rayhunter-root" to launch the telnet shell. This is only needed for installation, and can be removed after upgrade. You can reinstall it using `./installer util tplink-start-telnet`.
|
|
2. One port trigger "rayhunter-daemon" to auto-start Rayhunter on boot. If you remove this, Rayhunter will have to be started manually from shell.
|
|
|
|
## Other links
|
|
|
|
For more information on the device and instructions on how to install Rayhunter without an installer (i.e. manually), please see [rayhunter-tplink-m7350](https://github.com/m0veax/rayhunter-tplink-m7350/)
|